02/22/2013

Duct Smoke Detectors - Are You Protected?

Don't let toxic fumes travel unchecked in your building

By

 

Your ductwork offers a host of pathways for smoke and fire to travel through. Use a duct smoke detector to cut off the recirculation of toxic fumes.

A fire starts in your building – an alarm sounds, fire doors activate, and occupants rush outside to safety. But what about your HVAC system?

"In an emergency, air duct systems can transfer smoke, toxic gases, and flame from one area to another, posing a serious hazard to life safety and property," explains Jim Kapparos, national sales manager for System Sensor, a manufacturer of fire alarm systems.

Take the infamous 1980 MGM Grand fire. While the fire was contained to the lower levels of the casino, most of the 85 deaths occurred on the upper floors from smoke inhalation and carbon monoxide poisoning. Faulty dampers accelerated the spread of dangerous fumes to stairwells and emergency passageways.

According to the official investigation report by NFPA, "the distribution of smoke throughout the high-rise tower through the heating, ventilation, and air equipment" was a major factor contributing to the death toll.

To safeguard your ductwork from becoming a pathway for fire, make sure your facility is protected by duct smoke detectors.

How Do They Work?
Duct detectors sample currents in the air handling equipment to determine if smoke or fumes are present. If smoke is detected, the device will close dampers, stop fans and blowers, and trigger an audible and visible signal at the fire control panel, Kapparos explains.

These actions provide early detection, allow facility personnel to investigate the cause, and can protect the air conditioning system itself from fire and smoke damage.

Typically found in large commercial and industrial facilities, duct smoke detectors are a code-mandated device where required by NFPA 72 (90A), NFPA 101, and the International Mechanical Code (IMC), says Kapparos.

Stipulations can also be found in the International Building Code, International Fire Code, and the Life Safety Code 101, adds Bernie Arends, who served as an origin and cause fire investigator for over 30 years and works as a sales associate for Inspection Reports Online.

While local code adoption varies, duct smoke detectors are most common for facilities with 5-ton or more cooling units.

"Duct smoke detectors are needed on HVAC units over 2000 cfm on the return side, and on units over 15,000 cfm on the supply and return sides," says Arends.

Some can also be interconnected to other duct detectors. If one senses smoke, the rest will switch their relays, with the triggered detector reporting to the fire alarm panel so the source can be pinpointed.


Pages: 1  2  View All  
 


Visit our website today to learn about the design flexibility of a Morton building and the endless possibilities of partnering with our designBUILD team.


Wood construction is both cost and energy efficient. Check out Morton Buildings and our designBUILD team online today to discover all the benefits of post-frame construction.


When choosing a metal-clad building for your next construction project, consider Morton Buildings, Inc., and their designBUILD team, we’ll make your dream a reality.

We Can Help You Reduce Energy by 30%

Our mission is to help our customers manage their buildings' energy costs, improve reliability, and enhance performance while having a positive impact on the environment.
CLICK HERE to find out how.

Add highly responsive multi-zone comfort to any building project, in any climate. Our CITY MULTI H2i R2- and Y-Series VRF systems give you flexibility to fit the needs of any building. Enjoy 100% heating capacity at 0°F outdoor ambient, and 85% heating capacity at -13°F outdoor ambient.  For more information, log on to www.mitsubishipro.com


Visit our website today to learn about the design flexibility of a Morton building and the endless possibilities of partnering with our designBUILD team.


Wood construction is both cost and energy efficient. Check out Morton Buildings and our designBUILD team online today to discover all the benefits of post-frame construction.


When choosing a metal-clad building for your next construction project, consider Morton Buildings, Inc., and their designBUILD team, we’ll make your dream a reality.

We Can Help You Reduce Energy by 30%

Our mission is to help our customers manage their buildings' energy costs, improve reliability, and enhance performance while having a positive impact on the environment.
CLICK HERE to find out how.

Add highly responsive multi-zone comfort to any building project, in any climate. Our CITY MULTI H2i R2- and Y-Series VRF systems give you flexibility to fit the needs of any building. Enjoy 100% heating capacity at 0°F outdoor ambient, and 85% heating capacity at -13°F outdoor ambient.  For more information, log on to www.mitsubishipro.com

 
comments powered by Disqus

Related Products

Interiors
Roofing
Tools, Services and Software