With an estimated 32 million disabled people in the workforce, it is recommended
that wherever possible, facility managers specify furnishings that meet the
Americans With Disabilities Act (ADA) regulations for commercial facilities.
However, ADA regulations do not address movable furniture. Despite this, several
furniture manufacturers have developed products that comply with ADA guidelines.
Use the following tips to assist in the specification of movable, ADA-compliant
furnishings.
When specifying wall- or panel-hung storage cabinets, facilities managers should
avoid industry-standard overhead units with heavy and awkward doors that can
slam shut in an uncontrolled manner. According to ADA regulations, the user
should exert no more than 5 pounds of pressure and should be able to operate
the door with a closed fist. Since workers may be in a wheelchair, the unit
should also permit operation from a seated position. The handle of the door
(as well as the cabinet contents) should never be higher than 54 inches to accommodate
side reach, nor more than 48 inches to accommodate front reach.
For freestanding filing and other storage cabinets, request alternative handles,
such as loops, which can be opened with a hook or closed fist. Drawer mechanisms
should be of the quality that allows fully loaded drawers to be operated with
no more than 5 pounds of force.
ADA regulations for panel systems require clear width in aisles between cubicles
to be a minimum of 36 inches, with a doorframe clear width of at least 32 inches,
allowing adequate room for wheelchair movement. Cubicles intended for wheelchair
use should contain worksurfaces no deeper than 24 inches and between 28 and
34 inches high. To accommodate side reach from a wheelchair, nothing in the
cubicle should be lower than 9 inches or higher than 54 inches off the floor.
Areas that require forward reach from a wheelchair should locate nothing lower
than 15 inches and nothing higher than 48 inches. Panel system doors should
have a lever handle to allow operation with a closed fist.
ADA also requires that protruding objects, such as countertops, cannot extend
more than 4 inches into aisles. Countertops and surfaces at which employees
or visitors stand, lean, or write should be 28 to 34 inches high above the finished
floor, and must not extend more than 4 inches into aisles to accommodate visitors
who use special transportation devices, or who cannot reach standard counters.
Adjustable-height tables are an excellent option for both commercial and academic
facilities. Easy-to-use, plan, and reconfigure for varying applications, they
can be adjusted and reconfigured to accommodate wheelchairs. Freestanding adjustable
worksurfaces maximize use of facility space, cut costs in reconfiguring offices,
and can reduce work-related injury costs.
If fixed-height tables are preferred, ensure that a "field fix" kit
is available, enabling tables to be raised several inches or completely removed
to fit the needs of different users, such as those in wheelchairs. ADA guidelines
state that tables provide a "cube" of unobstructed knee space that
measures 27 inches high by 30 inches wide by 19 inches deep.
ADA-compliant furnishings are a crucial part of creating a comfortable, flexible,
productive, and effective facility, which ultimately is every facilities manager's
goal.