Prescriptions Don’t Do it All, Either

 

Richard (Dick) L. Fricklas

Richard (Dick) L. Fricklas was technical director emeritus of the Roofing Industry Educational Institute prior to his retirement. He is co-author of The Manual of Low Slope Roofing Systems, and continues to participate in seminars for the University of Wisconsin and RCI Inc.-The Institute of Roofing, Waterproofing, and Building Envelope Professionals. His honors include the William C. Cullen Award and Walter C. Voss Award from ASTM, the J. A. Piper Award from NRCA, and the James Q. McCawley Award from the MRCA. Dick holds honorary memberships in both ASTM and RCI Inc.

By Richard L. Fricklas

In recent Roofing News issues, I’ve been discussing the performance of roofing systems and exploring some moderately successful attempts at quantifying the variables you might encounter in a roofing project and their needed levels of performance. An ultimate success would mean that any system (regardless of composition) meeting the stated criteria could be chosen and succeed.

I also concluded that the American roofing industry is still a long way from applying total performance criteria.Perhaps the success of ASTM E936 for bituminous roofing over insulated steel decks (read Roof-SystemPerformance III) would’ve had more impact if the industry had not moved into elastomeric, polymer-modified bitumen, thermoplastics, spray polyurethane foam (SPF), and metal systems. Despite the fact that these later roof systems lacked the 100-plus years of experience of BUR, the products and systems moved along nicely.

Petroleum and Labor Considerations
While SPF, metal roofing, and single-ply systems were available as early as the 1960s, it took the oil embargo of 1973-1974 to jumpstart these as viable alternatives to the traditional hot built-up roof. With petroleum in short supply and inflation rampant, these systems were now suddenly viable and competitive – not merely curiosities.

Had E936 been widely accepted back then, the BUR industry would not have introduced two-ply BUR systems and told everyone that “one plus one equals four.” There was little or no research done to assure people that this was true.

Europeans faced labor shortages and extreme pricing of petroleum long before these became considerations in the United States. Polymer-modified bitumen, through aggressive testing and standard development, did prove that two modified-bituminous (MB) sheets equaled four BUR plies, and could perform without a flood coat and aggregate surfacing to boot. (Read Roof-System Performance II for a list of current ASTM standards and test methods for MB.)

When Prescriptive Specifications Fail
Prescriptive specifications work only when users have years – or even decades or centuries – of experience with a product/system. If it remains unchanged over that long time period, you can have a high degree of confidence that the product/system will still work today.

A graphic illustration of how this can go wrong is ASTM D41 for asphalt roof primer. The specification was originally issued in 1917. There are no performance requirements in it and no tests to verify that a particular product is a primer, that it improves adhesion to a variety of substrates, or that using the primer is better than not using one at all. Basically, D41 just calls for no less than 35-percent solvent and the rest asphalt, and that it be thin enough to flow through a calibrated orifice in not less than 25, or more than 125, seconds (i.e. not be too thin or too thick).

Since the product had only two components, and experience has proven that primer improves adhesion to cementitious, porous, greasy, oily, or dirty surfaces, it’s used regularly both in new construction and in the maintenance, repair, and recoating of most substrates.

Unfortunately, concerns over volatile organic compounds (VOCs) have become an environmental issue. VOCs contribute to smog generation, and the entire coatings industry (not just roofing) has had to find ways to comply with new regulations regarding VOCs. Catalyzed, solvent-free liquids are now available, as are water-based materials. For asphalt primer, however, if we reduce the volatile organic component (i.e. the solvent), the outcome is a thicker material (with more asphalt) that’s more of a coating than a penetrating primer. It no longer meets its intended use. ASTM D1079 defines a primer as “thin liquid bitumen applied to a surface to improve the adhesion of heavier applications of bitumen and to absorb dust.”

In 2005, the ASTM Subcommittee D08.05 that has jurisdiction over D41 decided, without any performance test data or documentation, that a thicker primer that might meet the VOC requirements was just fine. Rather than retain the maximum flow limit using the ASTM Standard Test Method for Saybolt Furol Viscosity (see Fig. 1) to 125 seconds (maximum) to drain the cup, the subcommittee decided to introduce a new Type II primer that increased the maximum allowable flow time to 800 seconds (more than 13 minutes). The committee never developed any performance test methods to confirm that this change to a much higher viscosity was not detrimental to the primer. No testing was done on dramatically changing a standard that had existed for 82 years, and there was no data to prove that it’s still a primer, or that its use as a thick syrup is better than no primer at all.


Fig. 1 - Saybolt Viscometer with Universal and Furol Orifice
All dimensions are in millimeters (inches)

Perhaps the industry is at fault for not having performance requirements for a primer in the past. But, creating a new D41 Type II (thick) primer solves nothing, and legitimizes a product that should not be used. The ASTM D08.05 subcommittee should either prove through performance tests that this Type II primer is acceptable, or delete it from D41. Where compliance with VOC regulations are absolutely necessary, we should either skip the primer or indicate that VOC-compliant primer does not meet D41.

In the real world, where D41 Type II primer is shipped to a roof project, the roofing contractor will find it too thick to apply.

Hopefully, the ASTM subcommittee will reconsider its efforts and will either withdraw Type II primer from its standards or develop performance tests to prove that this substance is fit for its intended use.

When the prescription for a prescriptive specification is changed without documentation, it has no value at all. Would you take aspirin if a company changed its formula without comprehensive FDA testing?

Resources:

 


Visit our website today to learn about the design flexibility of a Morton building and the endless possibilities of partnering with our designBUILD team.


Wood construction is both cost and energy efficient. Check out Morton Buildings and our designBUILD team online today to discover all the benefits of post-frame construction.


When choosing a metal-clad building for your next construction project, consider Morton Buildings, Inc., and their designBUILD team, we’ll make your dream a reality.

We Can Help You Reduce Energy by 30%

Our mission is to help our customers manage their buildings' energy costs, improve reliability, and enhance performance while having a positive impact on the environment.
CLICK HERE to find out how.

 


Tennant Company is a recognized leader in designing, manufacturing and marketing solutions that help create a cleaner, safer, healthier world. With thousands of satisfied customers already using award winning ec-H2O technology, why not see what you're missing? Test ec-H2O on your soils in your facility. Get a free demo.


Tennant Company is a recognized leader in designing, manufacturing and marketing solutions that help create a cleaner, safer, healthier world. With thousands of satisfied customers already using award winning ec-H2O technology, why not see what you're missing? Test ec-H2O on your soils in your facility. Get a free demo.

 

Replace core drilling with Connectrac In-Carpet and On-Floor Wireways, the proven connectivity solution in open interior spaces of all kinds. These elegant low-profile wireways are great for AV / telecom connectivity wherever it’s needed.

 

Add highly responsive multi-zone comfort to any building project, in any climate. Our CITY MULTI H2i R2- and Y-Series VRF systems give you flexibility to fit the needs of any building. Enjoy 100% heating capacity at 0°F outdoor ambient, and 85% heating capacity at -13°F outdoor ambient.  For more information, log on to www.mitsubishipro.com


Visit our website today to learn about the design flexibility of a Morton building and the endless possibilities of partnering with our designBUILD team.


Wood construction is both cost and energy efficient. Check out Morton Buildings and our designBUILD team online today to discover all the benefits of post-frame construction.


When choosing a metal-clad building for your next construction project, consider Morton Buildings, Inc., and their designBUILD team, we’ll make your dream a reality.

We Can Help You Reduce Energy by 30%

Our mission is to help our customers manage their buildings' energy costs, improve reliability, and enhance performance while having a positive impact on the environment.
CLICK HERE to find out how.

 


Tennant Company is a recognized leader in designing, manufacturing and marketing solutions that help create a cleaner, safer, healthier world. With thousands of satisfied customers already using award winning ec-H2O technology, why not see what you're missing? Test ec-H2O on your soils in your facility. Get a free demo.


Tennant Company is a recognized leader in designing, manufacturing and marketing solutions that help create a cleaner, safer, healthier world. With thousands of satisfied customers already using award winning ec-H2O technology, why not see what you're missing? Test ec-H2O on your soils in your facility. Get a free demo.

 

Replace core drilling with Connectrac In-Carpet and On-Floor Wireways, the proven connectivity solution in open interior spaces of all kinds. These elegant low-profile wireways are great for AV / telecom connectivity wherever it’s needed.

 

Add highly responsive multi-zone comfort to any building project, in any climate. Our CITY MULTI H2i R2- and Y-Series VRF systems give you flexibility to fit the needs of any building. Enjoy 100% heating capacity at 0°F outdoor ambient, and 85% heating capacity at -13°F outdoor ambient.  For more information, log on to www.mitsubishipro.com


 
comments powered by Disqus

Related Products

Flooring
Energy Management
Communications

Sponsored Links