ASHRAE Publishes New Version of IAQ Standard

 
New indoor air quality standard seeks to clarify previous version.

Newly published ANSI/ASHRAE Standard 62.1-2013, Ventilation for Acceptable Indoor Air Quality, contains several revisions aimed to help industry professionals better meet its requirements.

“The 2013 version of Standard 62.1 continues the trend of increasing clarity while adding flexibility,” says Roger Hedrick, Standard 62.1 committee chair. “These changes will allow designers and building operators to meet the requirements of the standard and provide adequate ventilation airflow to occupants while reducing excess ventilation and the associated energy consumption.“

The 2013 edition of the standard revises and improves the standard in several ways. A number of changes remove inconsistencies within the standard and improve clarity. Significant updates include:

  • Zone Air Distribution Effectiveness is modified to increase the ventilation effectiveness of underfloor air distribution systems that meet certain conditions. 
  • Requirements for the quality of water used in humidification systems are modified and clarified.
  • Building level pressurization requirements are clarified, including an added definition of “exfiltration.” 
  • A performance alternative to the prescriptive exhaust rates has been included.  This approach differs from the Indoor Air Quality Procedure, the existing performance-based method for setting supply ventilation rates, in that monitoring of the concentrations of contaminants of concern is required and provides the basis for control of exhaust flow rates. 
  • The filtration requirement on air entering wetted cooling coils has been modified to change the MERV rating from 6 to 8.  This change will reduce potential for particulate deposition on the coils that could lead to biological or other contamination on the coils. 
  • Toilet exhaust air that is cleaned to Class 1 may be recirculated. 

More information can be found on the ASHRAE website.

 


Visit our website today to learn about the design flexibility of a Morton building and the endless possibilities of partnering with our designBUILD team.


Wood construction is both cost and energy efficient. Check out Morton Buildings and our designBUILD team online today to discover all the benefits of post-frame construction.


When choosing a metal-clad building for your next construction project, consider Morton Buildings, Inc., and their designBUILD team, we’ll make your dream a reality.

We Can Help You Reduce Energy by 30%

Our mission is to help our customers manage their buildings' energy costs, improve reliability, and enhance performance while having a positive impact on the environment.
CLICK HERE to find out how.

Add highly responsive multi-zone comfort to any building project, in any climate. Our CITY MULTI H2i R2- and Y-Series VRF systems give you flexibility to fit the needs of any building. Enjoy 100% heating capacity at 0°F outdoor ambient, and 85% heating capacity at -13°F outdoor ambient.  For more information, log on to www.mitsubishipro.com


Visit our website today to learn about the design flexibility of a Morton building and the endless possibilities of partnering with our designBUILD team.


Wood construction is both cost and energy efficient. Check out Morton Buildings and our designBUILD team online today to discover all the benefits of post-frame construction.


When choosing a metal-clad building for your next construction project, consider Morton Buildings, Inc., and their designBUILD team, we’ll make your dream a reality.

We Can Help You Reduce Energy by 30%

Our mission is to help our customers manage their buildings' energy costs, improve reliability, and enhance performance while having a positive impact on the environment.
CLICK HERE to find out how.

Add highly responsive multi-zone comfort to any building project, in any climate. Our CITY MULTI H2i R2- and Y-Series VRF systems give you flexibility to fit the needs of any building. Enjoy 100% heating capacity at 0°F outdoor ambient, and 85% heating capacity at -13°F outdoor ambient.  For more information, log on to www.mitsubishipro.com

 
11/21/2014

Framework allows users a better look at roofing's environmental impact.

11/20/2014

Study finds paper towel dispensers carry far fewer germs.

11/19/2014

Tool will help manage information during power outages.

11/18/2014

Requirements include energy, IEQ, and sustainability updates.

11/17/2014

Group of 17 properties earn energy efficiency designation.

11/14/2014

Water conservation efforts see results.

11/13/2014

Study shows sustainable investments weather the winter.

11/12/2014

Standard focuses on occupant health.

11/11/2014

EPA says cleanup will cost hundreds of thousands of dollars.

11/10/2014

Methane will be used as a fuel source.

11/07/2014

ASTM to target roofing material diversion rates. 

11/06/2014

ORNL scientists look to the future of renewable energy integration.

11/05/2014

Lawsuits unlikely to convince polluters to change opposition to legislative reform. 

11/04/2014

Green building investment jumps in 2013. 

11/03/2014

Study shows difference between reported and measured occupant behavior

10/31/2014

Report shows energy modeling as key to improving building performance

10/30/2014

Report shows healthy features and practices yield results.

10/29/2014

USGBC announces two more years to prepare for LEED v4.

10/28/2014

Current projects could replace up to 8% of the Army’s energy use.

10/27/2014

Report shows increased occupant engagement in offices with green features.

Page 1 of 47
FirstPrevious[1]2345678910NextLast

Upcoming Webinars

Sponsored Links