Assessing Video Quality

02/27/2017 | By Justin Feit

How to set priorities for security cameras

Having reasonable expectations is especially important for video quality. Speak with a security professional to learn the details of your cameras’ performance.

Cameras aren’t able to capture every single image with perfect clarity. When setting expectations for video quality, know the different levels of identification a camera can provide.

“Within the industry, one of the metrics we use to define the quality of the picture is pixels per foot,” says Michael Silva, Principal at Silva Consultants in Covington, WA. “Generally speaking, in order to identify a person, you need to have 60-80 pixels per foot on the screen. In an entry, you would design your camera system so any object in the doorway would appear 60-80 pixels per foot on the screen.”

There are four distinct levels of identification and recognition with cameras:

  • Identify: The point at which you can reasonably tell that the image is of a certain person (40+ pixels per foot)
  • Recognize: You can verify somebody’s identity in the image because you know him or her (20-40 pixels per foot)
  • Observe: You can somewhat tell what the person is doing and in which direction he or she is walking (10-20 pixels per foot)
  • Detect: You are able to see something moving, but are unable to distinguish anything specific like clothing or faces (5-10 pixels per foot)

The Keys to Implementing an Effective Surveillance System

Important considerations for upgrading or installing new security
cameras in your facility

Click here for more information.

As an object gets closer to the camera, the level of recognition and identification changes. For example, a camera shining down on a parking lot will have “identify” coverage directly beneath it, “recognize” coverage around 20 feet out, “observation” range 30 to 40 feet away, and “detection” at the far end of the camera range, according to Silva.

Connectrac® wireways are the new standard for bringing power & communications cable management to all interior applications. Free yourself from core drilling!

Surpass State Energy Requirements with Dual-Cooling Data Center CRAC Technology

See how professionals like you are taking advantage of the highest performing precision cooling system for their computer rooms and data centers, and why Data Aire is fast-becoming the number one choice for facility managers and building owners looking to decrease their energy consumption. 

Data Aire understands how digital technology and data gravity is rapidly impacting and transforming businesses. That’s why they developed ultra-efficient cooling technology to support the most modern (and not-so-modern) data centers.  Learn how One Wilshire in Los Angeles, one of the most advanced carrier hotels today, is surpassing California's strict energy efficiency requirements with Data Aire’s purpose-built system, which provide full-economization for 260 days – almost 72% of the year. That’s a measurable savings! Furthermore, the projected PUE on an annual basis for a full load is at or below 1.2.

Connectrac® wireways are the new standard for bringing power & communications cable management to all interior applications. Free yourself from core drilling!

Surpass State Energy Requirements with Dual-Cooling Data Center CRAC Technology

See how professionals like you are taking advantage of the highest performing precision cooling system for their computer rooms and data centers, and why Data Aire is fast-becoming the number one choice for facility managers and building owners looking to decrease their energy consumption. 

Data Aire understands how digital technology and data gravity is rapidly impacting and transforming businesses. That’s why they developed ultra-efficient cooling technology to support the most modern (and not-so-modern) data centers.  Learn how One Wilshire in Los Angeles, one of the most advanced carrier hotels today, is surpassing California's strict energy efficiency requirements with Data Aire’s purpose-built system, which provide full-economization for 260 days – almost 72% of the year. That’s a measurable savings! Furthermore, the projected PUE on an annual basis for a full load is at or below 1.2.


Related Coverage