New Chiller Technology and Imaginative Renovation Create Showplace at Cal State

May 25, 2005

The expansive yet graceful Acacia Court Building in Stockton, CA - originally a state hospital - has been given a new life. An extensive renovation has converted this 1920s, 100-yard-long concrete building into a showplace of University Park, located in Stockton’s historic Magnolia District. The neighborhood is being redesigned as a “live, work, walk” development, and Acacia Court is home to the satellite campus of California State University, Stanislaus-Stockton. Students and staff occupy part of the first floor of the sprawling building; future plans include expansion into other sections as well. The renovation draws on unique technology, including an HVAC system designed around a new frictionless, magnetic bearing centrifugal chiller from McQuay - with impressive results. The chiller consumes far less power, costs less to operate, and generates far less noise than conventional chillers. 

In 2002, The Grupe Co., a respected California developer, was awarded the University Park contract to develop the area into classrooms, offices, shops, apartments, and a community center. As many as 32 buildings were razed; 19 were renovated. Part of the goal was to keep floorplan changes to a minimum, primarily as a “renovate to suit” project.

As part of a thorough evaluation, The Grupe Co. determined that the HVAC system was high on the list of systems to be updated at Acacia Court. The existing system included two chiller units dating from the 1950s, and some of the piping for them had collapsed.  “The efficiency of the old system was really poor,” says Chris Rasmussen, a member of the facility management department at The Grupe Co. “We explained to the university that the building needed a new chiller, along with new piping and a cooling tower.”

A New Kind of Chiller for an Old Building
The McQuay frictionless chiller features magnetic bearing compressor technology that is oil-free. This design significantly reduces sound levels, because the magnetic bearings eliminate the metal-to-metal contact noise of conventional bearings. Sound pressure ratings are as low as 77 dBA per ASHRAE Standard 575. Energy performance is also revolutionary. The McQuay frictionless centrifugal chiller operates as low as 0.375 kW/ton IPLV, the most efficient performance in its tonnage range in the industry. Full load performance is as low as 0.62 kW/ton - about 32-percent more efficient than screw compressor chillers. 

“The magnetic bearing technology of the McQuay frictionless centrifugal chiller provides superior energy efficiency by eliminating the high friction losses of conventional centrifugal compressors,” said Daryl Showalter, director of marketing, McQuay chiller products. “Variable frequency drives unload the chiller to 10 percent of full load. The chiller requires less than 5 amps to start, compared to 500 to 600 amps for a traditional screw compressor chiller. And, because magnetic bearings require no lubrication, there is no need for oil heaters, oil coolers, oil pumps, or oil piping.”

For more details on the chiller, the following articles are available for download:  “Efficient, Quiet and Oil-free,” from (www.go.mcquay.com); and “Frictionless Chiller Compressor Technology,” published in the January 2004 issue of HPAC Engineering, available at (www.mcquay.com). 

With proven magnetic bearings, oil-free compressors, and digital electronic controls, the McQuay frictionless chiller in the Acacia Court Building at the Stockton campus offers the highest part load efficiency in its tonnage range available in the industry. Compact enough to fit through a standard 3-foot door, the chiller can deliver savings for both new and retrofit projects.

“A Really Good Experience”
Despite the completely new technology and design, installation went smoothly.  “We had a really good experience,” said Rasmussen. “We completed 90 percent of the installation work with our own maintenance staff, which really helped reduce the cost. And since the system went online, there has been zero unscheduled downtime because of problems; only scheduled downtime for a couple of software upgrades.”

The two compressors of the frictionless chiller operate on a common refrigerant circuit, improving system reliability. In the event of a mechanical or electrical problem, one of the two compressors can continue to operate until repairs can be made. “If there is a problem with one compressor, we can still run with a 60-percent load on the other one,” said Rasmussen. 

The MicroTech IIdigital unit controller on the chiller effectively runs and monitors the chiller operation. The chiller is currently run based on a timeclock input because there are not as many maintenance issues with the magnetic bearing compressors. When the budget allows, the staff can integrate the MicroTech II chiller using BACnet® , LonTalk® or Modbus® protocol, thanks to the Protocol Selectabilityfeature of the unit controller.

Saving on Power, Maintenance, and Cost
“As far as cost-saving goes, it’s just incredible,” said Rasmussen. “The old chiller required 1,000 amps per leg at start-up. By contrast, when the new chiller starts up, each compressor takes only 7 to 10 amps. Also, it ramps up more slowly, so we don’t require a big surge of electricity in the beginning, which would be quite costly for the state.”

Maintenance is equally worry-free. With the magnetic bearings compressors, the oil handling equipment of the chiller is eliminated. There is no need for oil pumps, oil reservoirs, oil coolers, etc. (and their associated maintenance costs) that are needed to maintain oil quality. The only requirement is to “punch tubes,” or clean the pipes with a rotary brush, and blow out dust from the controls. “That’s our PM (planned maintenance) for the chiller,” said Rasmussen. “One other task we avoided is having to replace the refrigerant type in the near future.” The McQuay frictionless chiller already uses HFC-134a refrigerant, which has no phase-out date.

Subtracting Noise
Noise is the other big plus with the frictionless chiller - or rather, minus, since noise is virtually absent. “We have an air compressor in the basement, and when the air compressor is running, we can't tell if the chiller is also running,” said Rasmussen. “We actually have to walk up to the unit to see if it’s still going. We also have a couple of screw chillers at the university, and you can hear them all the way up from the basement to the first floor. They’re totally different from the McQuay chiller.”

For the university, the quiet new chiller makes the old building more useable as well as more efficient. While only a portion of the building is currently occupied, development plans include moving other university departments, as well as a computer lab, to Acacia Court.

Students and staff who use the building now and in the future will benefit not only from the renovated building and its technologically advanced chiller, but also the entire “liveable” concept of the Magnolia District.

Voice your opinion!

To join the conversation, and become an exclusive member of Buildings, create an account today!

Continue Reading

Sponsored Recommendations

Building Better Schools

Download this digital resource to better understand the challenges and opportunities in designing and operating educational facilities for safety, sustainability, and performance...

Tips to Keep Facility Management on Track

How do you plan to fill the knowledge gap as seasoned facility managers retire or leave for new opportunities? Learn about the latest strategies including FM tech innovations ...

The Beauty & Benefits of Biophilic Design in the Built Environment

Biophilic design is a hot trend in design, but what is it and how can building professionals incorporate these strategies for the benefits of occupants? This eHandbook offers ...

The Benefits of Migrating from Analog to DMR Two-Way Radios

Are you still using analog two-way radios? Download this white paper and discover the simple and cost-effective migration path to digital DMR radios that deliver improved audio...